Mississippi power outages: what size power station you need (MS)
In 2025, the average Mississippi electricity customer lost power for 8.4 hours, across 2.59 outages (EIA). To keep a fridge, router and lights running through one average outage you need about 403 Wh.
One average Mississippi (MS) outage lasted 3.2 hours (501.2 SAIDI minutes divided by 2.59 SAIFI interruptions). Covering Mississippi's full 8.4-hour annual outage total without recharging requires 1,047 Wh. Excluding major storm events, Mississippi customers averaged 5.1 hours (305.5 minutes) across 2.03 non-storm interruptions, ranking #5 of 51 states for total outage duration (compared with 9.5 hours in 2024).
Three lowest $/Wh stations covering an average Mississippi outage (403 Wh)
| $/Wh | Price | Capacity (Wh) | Output (W) | Chemistry | Product | Buy |
|---|---|---|---|---|---|---|
| $0.08 | $149 | 1,920 Wh | 2,500 W | LiFePO4 | ALLPOWERS R2500 V2 + SE160 160W Solar Panel Solar Generator Kit | Buy at ALLPOWERS Store for $149 |
| $0.29 | $899 | 3,072 Wh | 3,600 W | LiFePO4 | Pecron F3000LFP Portable Power Station 3600W 3072Wh | Buy at Pecron Store for $899 |
| $0.31 | $629 | 2,048 Wh | 2,400 W | LiFePO4 | FOSSiBOT F2400 Portable Power Station | Buy at FOSSiBOT Store for $629 |
Mississippi residential electricity price and 1,000 Wh grid recharge cost
Mississippi residential electricity averaged 14.43 cents per kWh in August 2026 (EIA), ranking #41 of 51 US jurisdictions (compared with 13.61 cents per kWh in August 2025). At Mississippi's 14.43 ¢/kWh tariff and 85% AC charging efficiency (16.98 ¢ per stored kWh), fully recharging a 1,000 Wh power station from a Mississippi wall outlet costs $0.17.
Solar panel output near Jackson, MS and 200 W recharge time
1 kW of fixed panels near Jackson makes about 3.22 kWh per day in December and 5.11 in June (NREL PVWatts). Recharging a depleted 1,000 Wh power station from a 200 W solar panel near Jackson, MS (32.30°N, -90.18°W) at 90% MPPT charge efficiency takes 1.7 days in December (579 Wh/day net solar harvest, ranking #13 of 51 for winter sun) and 1.1 days in June (919 Wh/day net solar harvest).
Monthly solar yield near Jackson, MS (1 kW DC array)
| Month | Jackson 1 kW monthly (kWh) | Jackson 1 kW daily (kWh/day) | 200 W panel net harvest (Wh/day) | Days to refill 1,000 Wh |
|---|---|---|---|---|
| January (Jackson, MS) | 107.5 kWh | 3.47 kWh/day | 624 Wh | 1.6 d |
| February (Jackson, MS) | 101.9 kWh | 3.64 kWh/day | 655 Wh | 1.5 d |
| March (Jackson, MS) | 135.8 kWh | 4.38 kWh/day | 789 Wh | 1.3 d |
| April (Jackson, MS) | 148.7 kWh | 4.96 kWh/day | 892 Wh | 1.1 d |
| May (Jackson, MS) | 155.8 kWh | 5.03 kWh/day | 905 Wh | 1.1 d |
| June (Jackson, MS) | 153.2 kWh | 5.11 kWh/day | 919 Wh | 1.1 d |
| July (Jackson, MS) | 152.8 kWh | 4.93 kWh/day | 887 Wh | 1.1 d |
| August (Jackson, MS) | 151.4 kWh | 4.88 kWh/day | 879 Wh | 1.1 d |
| September (Jackson, MS) | 146.8 kWh | 4.89 kWh/day | 881 Wh | 1.1 d |
| October (Jackson, MS) | 145.6 kWh | 4.70 kWh/day | 845 Wh | 1.2 d |
| November (Jackson, MS) | 122.0 kWh | 4.07 kWh/day | 732 Wh | 1.4 d |
| December (Jackson, MS) | 99.7 kWh | 3.22 kWh/day | 579 Wh | 1.7 d |
Data sources and verification dates for Mississippi
- Mississippi outage duration and frequency: EIA Electric Power Annual, Table 11.3 (2025 and 2024) (Mississippi SAIDI with major events: 501.2 minutes; SAIFI with major events: 2.59 interruptions; 77.6% of Mississippi customers reported; fetched 2026-11-06).
- Mississippi residential electricity price: EIA Electric Power Monthly, Table 5.6.A (August 2026) (Mississippi residential retail rate: 14.43 cents per kWh in August 2026; fetched 2026-11-06).
- Jackson, Mississippi solar irradiance and DC yield: NREL PVWatts V8 (NREL PVWatts V8 / NASA POWER Tilted Irradiance Climatology (1 kW DC, tilt=lat, losses=14%)) (reference city: Jackson, MS at 32.2988°N, -90.1848°W; fetched 2026-11-06).
Compare Mississippi against all 50 US states and DC on the state outage and solar hub.